Rev Bras Ortop ; 52(1): 35-39, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28194379

RESUMO

OBJECTIVE: This study aimed to evaluate the inter- and intra observer reproducibility of the radiographic score of consolidation of the tibia shaft fractures. METHODS: Fifty-one sets of radiographs in anteroposterior (AP) and profile (P) of the tibial shaft treated with intramedullary nail were obtained. The analysis of X-rays was performed in two stages, with a 21-day interval between assessments by a group of nine evaluators. To evaluate the reproducibility of RUST score between the evaluators, the intra-class correlation coefficient (ICC) with a 95% confidence interval was used. ICC values range from +1, representing perfect agreement, to -1, complete disagreement. RESULTS: There was a significant correlation among all evaluators: ICC = 0.87 (95% CI 0.81 to 0.91). The intraobserver agreement proved to be substantial with ICC = 0.88 (95% CI 0.85 to 0.91). CONCLUSION: This study confirms that the RUST scale shows a high degree of reliability and agreement.


OBJETIVO: Avaliar a reprodutibilidade inter e intraobservador do escore radiográfico de consolidação das fraturas (RUST) da diáfise da tíbia. MÉTODOS: Foram obtidos 51 conjuntos de radiografias nas incidências anteroposterior (AP) e perfil (P) da diáfise da tíbia tratadas com haste intramedular. A análise das radiografias foi feita em dois momentos, com intervalo de 21 dias entre as avaliações, por nove avaliadores. Para avaliar a reprodutibilidade do escore RUST entre os avaliadores foi usado o coeficiente de correlação intraclasse (CCI) com intervalo de confiança de 95%. O valor do CCI varia de +1, que representa concordância perfeita, a −1, que corresponde a total discordância. RESULTADOS: Houve uma concordância significativa entre todos os avaliadores: CCI = 0,87 (IC 95% 0,81 a 0,91). A concordância intraobservador mostrou-se substancial, com CCI = 0,88 (IC 95% 0,85 a 0,91). CONCLUSÃO: Este trabalho confirma que a escala RUST apresenta um elevado grau de confiabilidade e concordância.

2.
Rev. bras. ortop ; 52(1): 35-39, Jan.-Feb. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-844084

RESUMO

ABSTRACT OBJECTIVE: This study aimed to evaluate the inter- and intra observer reproducibility of the radiographic score of consolidation of the tibia shaft fractures. METHODS: Fifty-one sets of radiographs in anteroposterior (AP) and profile (P) of the tibial shaft treated with intramedullary nail were obtained. The analysis of X-rays was performed in two stages, with a 21-day interval between assessments by a group of nine evaluators. To evaluate the reproducibility of RUST score between the evaluators, the intra-class correlation coefficient (ICC) with a 95% confidence interval was used. ICC values range from +1, representing perfect agreement, to -1, complete disagreement. RESULTS: There was a significant correlation among all evaluators: ICC = 0.87 (95% CI 0.81 to 0.91). The intraobserver agreement proved to be substantial with ICC = 0.88 (95% CI 0.85 to 0.91) . CONCLUSION: This study confirms that the RUST scale shows a high degree of reliability and agreement.


RESUMO OBJETIVO: Avaliar a reprodutibilidade inter e intraobservador do escore radiográfico de consolidação das fraturas (RUST) da diáfise da tíbia. MÉTODOS: Foram obtidos 51 conjuntos de radiografias nas incidências anteroposterior (AP) e perfil (P) da diáfise da tíbia tratadas com haste intramedular. A análise das radiografias foi feita em dois momentos, com intervalo de 21 dias entre as avaliações, por nove avaliadores. Para avaliar a reprodutibilidade do escore RUST entre os avaliadores foi usado o coeficiente de correlação intraclasse (CCI) com intervalo de confiança de 95%. O valor do CCI varia de +1, que representa concordância perfeita, a -1, que corresponde a total discordância. RESULTADOS: Houve uma concordância significativa entre todos os avaliadores: CCI = 0,87 (IC 95% 0,81 a 0,91). A concordância intraobservador mostrou-se substancial, com CCI = 0,88 (IC 95% 0,85 a 0,91) . CONCLUSÃO: Este trabalho confirma que a escala RUST apresenta um elevado grau de confiabilidade e concordância.


Assuntos
Humanos , Masculino , Feminino , Consolidação da Fratura , Radiografia , Tíbia
SELEÇÃO DE REFERÊNCIAS